11.1 List of Parameters
11.1.2 List of Parameters
11-18
PnBB6
2
/N-CL
(Reverse External
Torque Limit Input)
Signal Allocation
0000h to
00C3h
0003h
After
restart
Setup page 5-12
PnBB7 2
Reserved
parameter
(Do not change.)
0000h to
00C3h
0003h
After
restart
Setup
PnBB8
2
E-STP
(Emergency Stop
Input)
Signal Allocation
0000h to
00C3h
00C0h
After
restart
Setup page 5-13
PnBB9 2
Reserved
parameter
(Do not change.)
0000h to
00C3h
0003h
After
restart
Setup
Continued on next page.
Continued from previous page.
Parameter
No.
Size Name
Setting
Range
Setting
Unit
Default
Setting
When
Enabled
Classi-
fication
Reference
n.X Signal Usage Method
0 Enable the reverse external torque limit when the input signal turns ON (closes).
1 Enable the reverse external torque limit when the input signal turns OFF (opens).
2 Always enable the reverse external torque limit.
3 Always disable the reverse external torque limit.
n.X Signal Terminal Number
Same as PnBA0 = n.X.
n.X Reserved parameter (Do not change.)
n.X Reserved parameter (Do not change.)
n.X Signal Usage Method
0 Enable an emergency stop when the input signal turns OFF (opens).
1 Enable an emergency stop when the input signal turns ON (closes).
2 Always enable the emergency stop.
3 Always disable the emergency stop.
n.X Signal Terminal Number
Same as PnBA0 = n.X.
n.X Reserved parameter (Do not change.)
n.X Reserved parameter (Do not change.)