EasyManua.ls Logo

Aastra Ascotel IntelliGate 2065 - Page 273

Aastra Ascotel IntelliGate 2065
1014 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Ascotel IntelliGate 2025/2045/2065
Part 2 Call Routing 273
Routing without Direct Dialling
A call without a suitable direct dial number is routed to the call destination via the
call distribution element allocated in the trunk group.
[1] One and the same trunk group cannot contain both analogue and digital network interfaces.
Fig. 2.62: Routing a call from the public network without direct dialling
Tab. 2.27: Setting the routing parameters
Direct dialling plan 1 (number of a direct dialling plan)
Call Distribution Element 1 (significant only if a suitable direct dial number is not found)
Direct dialling plan 1:
DD number 20 2 (reference number of a call distribution element)
Call distribution element 2:
Destinations Switching position 1: SC 220 + KT
Incoming connections Number of connections allowed simultaneously
Parameter Parameter value
Trunk group 1:
Network interfaces Network interfaces in this trunk group
Incoming connection Number of connections allowed simultaneously
Parameter Parameter value
Network
connections
Trunk group 1 (DSS1)
-> Call distribution 1
-> Direct dialling plan 1
DD No. -
DD No. 20
-> Call distribution 3
Trunk group 2 (PSS1)
-> Direct dialling plan 2
Direct dialling plan 1
Direct dialling plan 2
Call distribution 1
Call distribution 2
Call distribution 3
1/n
220
PISN
Subscriber
KT line
Switchover
T
T2
a/b
[1]
-> SC 220 + KT
-> SC 220 + KT
-> SC 220 + KT
2/n
220
3/n
220
T
T2
Se
PINX 1
PINX 1
PINX 2
haz0728aaena0
Exchange
222 22 20