848 Enabling local access Part 5
• Access type / login name
• Interface card number, port number, MSN
• Type of access (remote / local)
• CLIP requirement
• Indication of the HEX rotary switch position
• Number of log entries
• Status indication of whether modification(s) has(have) been carried out
This log can be read by each and every password holder.
There are five access logs (i.e. one for each authorization level and one for failed
access attempts), each of which stores the last twenty entries:
• Access attempts
• Attendant
• System Manager
•Installer
• Support / Service Centre
3.4.1 Retrieving the log data
The PBX monitors and saves all the accesses as well as failed access attempts.
These lists can be retrieved locally or remotely.
For access requirements, see "Connection options for internal access", page 838
and "Connection options for external access", page 839.
In the case of a local access, the data field "Subscriber Name" differentiates
between access to the configuration menu via PC with ISDN card, Pocket Adapter
or V.24. In AIMS the login name is also recorded, where available.
CLIP verification
If the setting "CLIP required?" is set to "Yes" in the configuration, remote
retrieval is possible only if the retrieving party logs in using a CLIP. The CLIP
number is also recorded by the access log.