EasyManua.ls Logo

Aastra Ascotel IntelliGate 2065 - 7.6.5 Protocol format

Aastra Ascotel IntelliGate 2065
1014 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Ascotel IntelliGate 2025/2045/2065
408 Call logging (CL) Part 2
7.6.5 Protocol format
This format is used for direct output on the printer. It is used if data acquisition is
not carried out on the data carrier of a corresponding system.
The structure with page header and subsequent data lines is designed to make
the protocol printout easier to read.
Page header
(does not contain any user data)
Tab. 2.108: Page header for protocol format
NO PISN number of Subscriber C.
SC Incoming call from the PISN, answered directly.
ID1 Subscriber A wants to use this CLIP to present himself. It appears on Subscriber C’s system ter-
minal display.
ID2 Caller’s CLIP verified by the public network. Displayed to the destination subscriber only if no
ID1 CLIP is available.
DEST1 This field is always empty for ICL output.
DEST2 PISN number of Subscriber C.
Content, text Structure Length Print offset
Form Feed FF, 0CH 1 0
Carriage Return CR, 0DH 1 0
Line Feed LF, 0AH 1 0
Space (2) SP 2 0
NO (CC) 'NO' ('CC') 2 2
Space (4) SP 4 4
SC 'SC '2 8
Space (1) SP 1 10
DATE 'DATE '5 11
Space (2) SP 2 16
TIME 'TIME '4 18
Space (2) SP 2 22
DURATION 'DURATION '5 24
Space (4) SP 4 29
EXCH 'EXCH '3 33
Space (5) SP 5 36
CHARGES 'CHARGES '7 41