Ascotel IntelliGate 2025/2045/2065
Part 3 Planning DECT systems 655
Handover setting
The "Handover Setting" menu is used for setting the operating mode required for
signalling the switch to another radio unit:
• "Show HO": from "Test" menu
•"
ß": presents one selection in each case (in succession)
• "None": no indication / signalling for a switch to another radio unit
• "Beep": indication / signalling for switch activated with acoustic signal
• "Disp": indication / signalling for switch activated with indication of the desti-
nation radio unit
• "Both": indication / signalling for switch over activated, with acoustic signal
and indication of the destination radio unit
• "Ok": accept choice and go back to "Test" menu
5.5.4 Radio units
Testing the radio unit voltage supply
The power supply is ensured by the plug-in power supply unit, which is
permanently connected to the radio unit. If a 230 VAC connection is not
available, the radio unit can be operated with a battery box.
Tab. 3.29: Connecting a battery to SUPPLY
The voltage must be between 9 and 15 V (DC voltage). The current consumption
is 230 mA. This means that with a capacity of 1.1 Ah the battery box can provide
up to 5 hours of measuring time.
SUPPLY Pin Function
1 Supply +
2 Supply -
3–
4–
5–
6–
64 25
3
1
haz0350aaxxa0