Ascotel IntelliGate 2025/2045/2065
Part 7 Operations supervision 951
4.6.9 Malfunctions with the Telecourier 900 pager system
(PS)
Tab. 7.36: Malfunctions with the PS
4.6.10 Malfunctions of the DECT radio unit
Tab. 7.37: Malfunctions of the DECT radio unit
No more ICL data is output via the V.24 Memory overflow if ICL printer is blocked
(the same memory is used).
• Clear the printer jam or, if necessary,
• Clear the OCL / ICL memory (see above)
Error description Error cause / error handling
Paging system (PS) does not work. • Check whether the PS has been configured
The PS receivers continue to ring after answering
(several search paths).
The search duration t
r
is set too short in the AIMS
configuration. t
r
must be ≥ the search duration set in
the PS.
• Adjust the search duration t
r
Error description Error cause / error handling
No radio connection in a coverage area. Check LED on radio unit.
Red LED flashing:
• Check power supply / line length of AD2 bus cable
(LED flashes briefly at regular intervals)
• Check AD2 bus cable (LED goes out briefly at reg-
ular intervals)
• Unplug AD2 bus cable for one minute, then recon-
nect
Green LED flashing long:
• All B channels busy
Radio unit not activated. • If LED on radio unit is flashing
– Radio unit in startup phase
– Radio unit defective
• If LED on radio unit not flashing
– Check trunk connections
– Radio unit defective
Error description Error cause / error handling