4.6.9 Malfunctions with the Telecourier 900 pager system
(PS)
Tab. 7.36: Malfunctions with the PS
4.6.10 Malfunctions of the DECT radio unit
Tab. 7.37: Malfunctions of the DECT radio unit
No more ICL data is output via the V.24 Memory overflow if ICL printer is blocked
(the same memory is used).
Clear the printer jam or, if necessary,
Clear the OCL / ICL memory (see above)
Error description Error cause / error handling
Paging system (PS) does not work. Check whether the PS has been configured
The PS receivers continue to ring after answering
(several search paths).
The search duration t
r
is set too short in the AIMS
configuration. t
r
must be the search duration set in
the PS.
Adjust the search duration t
r
Error description Error cause / error handling
No radio connection in a coverage area. Check LED on radio unit.
Red LED flashing:
Check power supply / line length of AD2 bus cable
(LED flashes briefly at regular intervals)
Check AD2 bus cable (LED goes out briefly at reg-
ular intervals)
Unplug AD2 bus cable for one minute, then recon-
nect
Green LED flashing long:
All B channels busy
Radio unit not activated. If LED on radio unit is flashing
Radio unit in startup phase
Radio unit defective
If LED on radio unit not flashing
Check trunk connections
Radio unit defective
Error description Error cause / error handling