Setting LCR to PINX 1:
• The digit sequence "60" is entered in the LCR table.
– All outgoing, PISN-internal calls whose phone number begins with "60" will
be analysed by LCR.
• In the routing table the entry for the first network provider stays blank. How-
ever, an alternative network provider is entered.
• Under normal conditions, calls whose phone number begin with "60" will be
routed in accordance with the subscriber configuration. If the normal path is
not available, the calls will be routed via the alternative network operator.
• The network operator table determines the route via which the alternatively
routed calls are to be routed.
• In the network operator table the PISN phone number must be converted into
an external direct dial number. The master number of PINX 2 is used for this
purpose without its direct dial portion. The direct dial portion is formed by
using the PISN subscriber number without regional prefix.
This means that all the subscribers on PINX 2 need only one entry in the LCR
configuration. This can only be achieved if the DDI numbers match the internal
subscriber numbers.
Tab. 2.71: Settings for overflow routing on PINX 1
Parameter Parameter value
LCR table:
• I60 (regional prefix for PINX 2) O-flow PINX 2 (allocate to routing table "O-flow PINX 2")
Routing table "O-flow PINX 2":
• Time zone x • Service provider: -
• Alternative service provider: PINX 2
• Times: Allocate the times for "PINX 2"
Network operator table:
• Network provider "PINX 2" Route 6
• Conversion rule 0666666<3-.> (master number of PINX 2 without three-digit
direct dial portion and the last three digits of the dialled phone
number. If, for example, SC A dials 60300, the number
0666666300 is used, which corresponds to the direct dial
number of SC B).
Route 6:
• Name PINX 2, subscriber
• Trunk groups 2
• Digit barring No (do not consult digit barring)
• Outgoing connections Number of connections allowed simultaneously
• Numbering plan identifier NPI E.164