Ascotel IntelliGate 2025/2045/2065
350 Call Routing Part 2
Planning the routes and trunk groups
To keep a network configuration as transparent as possible, it is a good idea
always to use the same trunk group and the same route for the same function on
all the PINXs. It makes sense, for example, to use trunk group 1 in each PINX for
connections to the public ISDN network as trunk group 1 has this initialization
value.
Settings on the source PINX (PINX 1):
Subscriber configuration:
A permanent CLIP number is configured for internal subscribers in Geneva,
which is transmitted unchanged along with each outgoing call to the public
network.
Least Cost Routing:
The initial digits of the numbers within the Zurich local rate zone are entered
in the LCR table and allocated a route via the routing and network operator
table
(see also "Least Cost Routing (LCR)", page 304).
Setting up routes:
All calls sent to the public network via Zurich are routed via a separate route.
Its configuration must
include the setting NPI = E.164 so that PINX 2 recognizes a call as external
and routes it accordingly.
All calls addressed to PINX 2 subscribers in Zurich are routed via another
route whose configuration contains the setting NPI = PNP.
Both routes can be allocated to the same trunk group.
Trunk group settings:
Network = Private
Protocol = PSS1
Automatic CLIP = Yes