Ascotel IntelliGate 2025/2045/2065
Part 3 System and Expansion Limits 597
In addition to the general system limits and limits per user-network interface the
maximum number of terminals connected to the system can also be limited by the
supply power available to the system.
With the AIMS Project Manager all these factors are automatically taken into
account, without any need for manual calculations. Manual calculation itself is
subject to the following principles:
Power supply-related limits per system
The number of permissible terminals per system depends on the power require-
ments of the individual terminals: The total power requirements of all connected
terminals must not exceed the power output of the power supply. The average
power requirements of terminals as indicated in Tab. 3.22 are used for the calcu-
lations.
Tab. 3.21: Power output of the power supply (-40 VDC)
Terminals as per
ETSI standard
• ISDN terminals
• ISDN PC cards
• ISDN LAN routers
• ISDN Terminal Adapters
30 60 250 8
a/b Terminals on a/b interfaces (total) 12 23 168
4)
1
Analogue, nationally
approved terminals
• Pulse dialling (PUL)
• Frequency dialling
(DTMF)
• Group 3 fax machines
• Answering machines
•Modems
12 23 168
5)
1
1)
DSP cards required.
2)
Maximum of 18 SB-8 radio units for operation on two AD2 interfaces in each case.
3)
Maximum of 2 call connections possible simultaneously.
4)
The Ascotel Voice Mail System occupies 2 or 4 a/b interfaces.
5)
For performance reasons only 56 terminals with pulse dialling are permitted.
2025 system 2045 system 2065 system
Available power output 28 Watt 28 Watt 70 Watt
Inter-
face
Terminal type System Terminals 2025 per
system
2045
per
system
2065
per
system
per
interface