Ascotel IntelliGate 2025/2045/2065
Part 4 Cabling interfaces 793
Transmission rate
Tab. 4.49: Setting the transmission rate
Flow control
Tab. 4.50: Setting the flow control
Terminal selection digit (TSD)
Usually the Pocket Adapter is addressed as Terminal 2.
Tab. 4.51: Setting the address
Notes:
The PA cannot be set with AIMS.
With AIMS a PA cannot be configured on to an interface.
Connected PAs are indicated in AIMS after a download (but cannot be
modified).
Switch S8 Switch S7 Switch S6 Transmission rate
ON ON ON Test mode
ON ON OFF 19200
ON OFF ON 9600
ON OFF OFF 4800
OFF ON ON 2400
OFF ON OFF 1200
OFF OFF ON 600
OFF OFF OFF reserved
Switch S5 Switch S4 Flow control
ON ON none
ON OFF Xon / Xoff
OFF ON Hardware with RTS / CTS
1)
1)
Factory setting. Essential for online operation with AIMS
OFF OFF Xon / Xoff and RTS / CTS
Switch S2 Address
ON 2. Terminal
OFF 1. Terminal