Lesson 3 Setting Up the Digital Capturing
331
Setting up the Timing for Selective Capturing
Selective Capturing lets you define for every vector of a capture
label whether you want data to be captured or not.
Especially when highest speed of capturing is needed, this mode is
to be preferred over the Sequential Mode, as the transfer of
undesired data to the workstation and later blending out of this
data by means of a vector variable can be avoided.
Of course, the full data filtering capabilities of a vector variable
can also be applied to data captured in Selective Mode, if this is
desired.
The timing for selective capturing can only be defined using
equation based setup.
For selective capturing, you use two specific edge actions in the
wave table to define when and when not capturing will be
performed:
Action C - Capture Data on this edge
Action D - Do not capture Data on this edge
Waveform and Device Cycle Definition for Selective Capturing