B13 BEST WASHING MACHINE SERVICE HANDBOOK
45
MAIN_WASH
VALVE
CV2
SS(x)_P0
S
S
(
x
)
_
F
2
t
VALVE_OPENING_COU
NT = 1
VALVE_OPENING_COUNT =
2
VALVE_OPENING_COU
NT = 3
VALVE_OPENING_COUNT
= N
VALVE_OPENING_COU
NT = 0
VALVE_OPENING_COU
NT = 1
VALVE_OPENING_COUNT
= M
NOTE:
Hot water intake applies for programmes
with 60C and above programme index.
For all programmes; value N is from
variable file and value M is infinite.
Heating Step
Saoking Heating Step
If hot water intake conditions are met, HV; if not, CV2
Safety:
Heater will be switched off
if water level falls below Pg
and main wash valve will
be driven to take water as
much as SS_Fg quantity.
Valve opening number is
increased by 1 in each
step.
Safety:
Heater will be switched off if water level
falls below Pg and main wash valve will
be driven to take water as much as
SS_Fg quantity.
Valve opening number is increased by 1
in each step.
No water will be taken in for Cottons
Eco.
VALVE_OPENING_COU
NT = 0
S
S
(
x
)
_
F
3
S
S
(
x
)
_
F
3
S
S
(
x
)
_
F
3
S
S
(
x
)
_
F
1
S
S
_
F
0
S
S
(
y
)
_
F
1
SS(y)_P0
VALVE_OPENING_COU
NT = 1
SS_Pg
HOT_WATER_VALVE
HV
VALVE_OPENING_COU
NT = 0
Cold Wash Step
VALVE_OPENING_COU
NT = 1
VALVE_OPENING_COUNT
= M
Cold Wash
Water Completion Step
Water Level
MAIN_WASH
VALVE
CV2
MAIN_WASH
VALVE
CV2
S
S
_
F
g
S
S
_
F
g
S
S
_
F
g
S
S
_
F
g
S
S
_
F
g
S
S
_
F
g
BETTER WATER INTAKE ALGORITHM – Graphical Display
HOT_WAT
ER_VALVE
HV
If hot water
intake
conditions
are met, HV; if
not, CV2
S
S
_
F
0
Postheating Wash Step
Soaking Wash Step
8. GENERAL OPERATION PRINCIPLE
8.1.Water Intake Profil
Figure 8.1 Water intake graphics