User's Manual 1162 Document #: LTRT-27055
Mediant 1000B Gateway & E-SBC
Parameter Description
Note: The x in the ini file parameter name
denotes the trunk number, where 0 is Trunk 1.
[CASFileName_x] Defines the CAS file name (e.g., 'E_M_WinkTable.dat') that
defines the CAS protocol, where x denotes the CAS file ID (0-7).
It is possible to define up to eight different CAS files by repeating
the parameter. Each CAS file can be associated with one or more
of the device's trunks, using the parameter CASTableIndex_x.
Note: For the parameter to take effect, a device reset is required.
CAS Table per Channel
configure voip > interface e1-t1 >
cas-channel-index
[CASChannelIndex]
Defines the loaded CAS protocol table index per B-channel
pertaining to a CAS trunk. The parameter is assigned a string
value and can be set in one of the following two formats:
CAS table per channel: Each channel is separated by a
comma and the value entered denotes the CAS table index
used for that channel. The syntax is <CAS index>,<CAS
index> (e.g., "1,2,1,2…"). For this format, 31 indices must be
defined for E1 trunks (including dummy for B-channel 16), or
24 indices for T1 trunks. Below is an example for configuring a
T1 CAS trunk (Trunk 5) with several CAS variants:
ProtocolType_5 = 7
CASFILENAME_0='E_M_FGBWinkTable.dat'
CASFILENAME_1='E_M_FGDWinkTable.dat'
CASFILENAME_2='E_M_WinkTable.txt'
CasChannelIndex_5 =
‘0,0,0,1,1,1,2,2,2,0,0,0,1,1,1,0,1,2,0,2,1,2,2
,2’
CASDelimitersPaddingUsage_5 = 1
CAS table per channel group: Each channel group is
separated by a colon and each channel is separated by a
comma. The syntax is <x-y channel range>:<CAS table
index>, (e.g., "1-10:1,11-31:3"). Every B-channel (including 16
for E1) must belong to a channel group. Below is an example
for configuring an E1 CAS trunk (Trunk 5) with several CAS
variants:
ProtocolType_5 = 8
CASFILENAME_2='E1_R2D'
CASFILENAME_7= E_M_ImmediateTable_A-Bit.txt'
CasChannelIndex_5 = ‘1-10:2,11-20:7,21-31:2’
Note:
To configure the parameter, the trunk must first be stopped.
Only one of these formats can be implemented; not both.
When the parameter is not configured, a single CAS table for
the entire trunk is used, configured by the parameter
CASTableIndex.
[CASTablesNum] Defines how many CAS protocol configurations files are loaded.
The valid range is 1 to 8.
Note: For the parameter to take effect, a device reset is required.
CAS State Machines Parameters
Note: To configure the CAS State Machine table using the Web interface, see ''Configuring CAS
State Machines'' on page 483. The CAS state machine can be configured only through the Web-
based management tool.
Generate Digit On Time Generates digit on-time (in msec).