EasyManua.ls Logo

AudioCodes Mediant 1000B - Page 711

AudioCodes Mediant 1000B
1281 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Version 7.2 711 Mediant 1000B Gateway & E-SBC
User's Manual 34. Routing SBC
IP Group for the second IP PBX ("Type" and "Port" tags are later used to identify
the IP PBX and assign it a local UDP port 6002 on the leg interfacing with the
proxy server):
General
Index
2
Name
PBX-2
Type
Server
SBC Advanced
Tags
Type=PBX;Port=6002
IP Group for the third IP PBX ("Type" and "Port" tags are later used to identify the
IP PBX and assign it a local UDP port 6003 on the leg interfacing with the proxy
server):
General
Index
3
Name
PBX-3
Type
Server
SBC Advanced
Tags
Type=PBX;Port=6003
IP Group for the proxy server ("Type" tag is later used to identify proxy server):
General
Index
4
Name
ITSP
Type
Server
SBC Advanced
Tags
Type=ITSP
3. Open the Call Setup Rules table (see Configuring Call Setup Rules on page 393), and
then configure the following Call Setup rules:
Uses the value of the "Type" tag name, configured in the IP Group's 'Tags'
parameter, as the source tag:
General
Index
1
Rule Set ID
1
Action
Action Subject
srctags.Type
Action Type
Modify
Action Value
param.ipg.src.tags.Type