CHAPTER72 Configuration Parameters Reference
Mediant 800 Gateway & E-SBC | User's Manual
Parameter Description
[0] = (Default) Disabled. Currently configured
users (usernames and passwords) are retained.
[1] = Default users are restored (see description
above) and all other configured users are
deleted.
Note:
For the parameter to take effect, a device reset
is required.
In addition to the ini file (see above), you can
also restore the default user accounts through
the following management platforms:
SNMP (restores default users and retains
other configured users):
1) Set acSysGenericINILine to
WEBPasswordControlViaSNMP = 1, and
reset the device with a flash burn (set
acSysActionSetResetControl to 1 and
acSysActionSetReset to 1).
2) Change the username and password in
the acSysWEBAccessEntry table. Use the
following format:
Username acSysWEBAccessUserName:
old/pass/new
Password acSysWEBAccessUserCode:
username/old/new
[WelcomeMessage]
configure system > welcome-
msg
Defines a welcome message displayed on the Web
interface's Web Login page.
The format of the ini file table parameter is:
[WelcomeMessage ]
FORMAT WelcomeMessage_Index =
WelcomeMessage_Text
[\WelcomeMessage]
For Example:
FORMAT WelcomeMessage_Index =
WelcomeMessage_Text
WelcomeMessage 1 =
"**********************************" ;
WelcomeMessage 2 = "********* This is a Welcome
message ***" ;
WelcomeMessage 3 =
"**********************************" ;
For more information, see Creating a Login
Welcome Message.
Note:
Each index row represents a line of text. Up to
20 lines (or rows) of text can be defined.
The configured text message must be enclosed
in double quotation marks (i.e., "...").
- 1157 -