89000109-002 xVue Touch Installation Manual
Rev 2 Page 2-7
© Honeywell International Inc. Do not copy without express permission of Honeywell.
For Use in Non-Certified Aircraft
Table 2-6 KMG 7010 Magnetometer Specifications
Characteristic Specification
Dimensions 3.70 x 5.83 x 1.33 inches (93.98 x 148.08 x 37.78 mm)
Weight 0.99 lbs (0.45 kgs) Max. Weight
Temperature -55 °C to +70°C
Altitude 55,000 ft.
Operating Voltage 9.0 to 32.2 VDC
(9VDC on battery backup, 11VDC for power-up, and 32.2VDC max)
Current Draw
(at 27.5 VDC)
80 mA Nominal, 25°C, after 2 minute warmup
200 mA Nominal, -55°C, after 2 minute warmup
700 mA Maximum, -55°C
Typical (28VDC): 0.08 AMP
Typical (14VDC): 0.16 AMP
Circuit Breaker 1 AMP for 28 VDC, 2 AMP for 14 VDC systems
Signal Inputs/Outputs Serial CAN Bus
Cooling Convection cooled. No external cooling required.
Connector Male 9-pin D-sub
Certifications TSO-C6d/ETSO-C6d (partial)
Table 2-7 MD32 Magnetometer Specifications
Characteristic Specification
Dimensions
(not incl. connector mate)
3.0 x 2.75 x 0.81 inches (LxWxH) (76.20 x 69.85 x 20.57 mm)
Weight 3.0 oz (.085 kg)
Temperature -55 °C to +70°C (-67°F to +158°F)
Altitude 55,000 ft.
Operating Voltage 7.0 to 32 VDC
Output Data ARINC 429 (proprietary format)
Mating Connector MCI P/N 8017287
Certifications TSO-C6e