EasyManua.ls Logo

BENDIXKing XVUE TOUCH - KG 71 EXP Pressure Ports; Figure 5-1 Pressure Port Fitting(S); Table 5-5 Pressure Port Descriptions

BENDIXKing XVUE TOUCH
280 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
89000109-002 xVue Touch Installation Manual
Rev 2 Page 5-8
© Honeywell International Inc. Do not copy without express permission of Honeywell.
For Use in Non-Certified Aircraft
5.3.2 KG 71EXP Pressure Ports
The air pressure interface for static and total pressure ports is provided via static and pitot fittings.
Details about the pressure ports are described in Table 5-5 Pressure Port Descriptions. An example of
straight and elbow pressure fittings is depicted in Figure 5-1 Pressure Port Fitting(s).
Figure 5-1 Pressure Port Fitting(s)
43 A429 TX1 A Out
44 A429 TX1 B Out
45 Chassis GND GND
46 CAN H In
47 CAN L In
48 A429 TX2 B Out
49 Interlock 1 In
50 Interlock 2 In
Table 5-5 Pressure Port Descriptions
Pressure
Name
KG71EXP IPT Adapter Ending Recommended Fitting Operational
Pressure Range
Pitot Pressure Nipple to 1/8 inch, NPT Male • Straight male AN816-4D
• Elbow male AN822-4D
(1.4 - 37) in Hg
Static Pressure Nipple to 1/8 inch, NPT Male • Straight male AN816-4D
• Elbow male AN822-4D
(1.4 - 32) in Hg
J71 Pin Description I/O
NOTE
THE CONNECTION OF KG 71EXP TO THE ORIGINAL PRESSURE DISTRIBUTION SYSTEM
MUST BE IN COMPLIANCE WITH 14 CFR 23.1323 AND 23.1325.

Table of Contents