EasyManua.ls Logo

BENDIXKing XVUE TOUCH - Table 2-8 KDC 100 EXP Data Converter Specifications; Table 2-9 KTP 73 Outside Air Temperature Probe Specifications

BENDIXKing XVUE TOUCH
280 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
89000109-002 xVue Touch Installation Manual
Rev 2 Page 2-8
© Honeywell International Inc. Do not copy without express permission of Honeywell.
For Use in Non-Certified Aircraft
Table 2-8 KDC 100EXP Data Converter Specifications
Characteristic Specification
Dimensions 3.70 x 5.83 x 1.33 inches (93.98 x 148.08 x 37.78 mm)
Weight 0.99 lbs (0.45 kgs) Max. Weight
Temperature -55 °C to +70°C
Altitude 55,000 ft.
Operating Voltage 14 to 28 VDC
Current Draw
(at 27.5 VDC)
80 mA Nominal, 25°C, after 2 minute warmup
200 mA Nominal, -55°C, after 2 minute warmup
700 mA Maximum, -55°C
Circuit Breaker 1 AMP for 28 VDC, 2 AMP for 14 VDC systems
Signal Inputs/Outputs Serial CAN Bus
Cooling Convection cooled. No external cooling required.
Connector Male 15-pin
Certifications TSO-C6d/ETSO-C6d (partial)
Table 2-9 KTP 73 Outside Air Temperature Probe Specifications
Characteristic Specification
Dimensions 1.65 x 1.75 x 1.00 inches (41.91 x 44.45 x 25.4 mm)
Weight 0.17 lbs (0.07 kgs) Max. Weight
Current Draw NA, not connected to the airplane power bus.
Operating Voltage Connected to the ADAHRS, no interface to the airplane power.
Circuit Breaker NA
Cooling Mounted outside the airplane. No cooling required.
Connectors 5 ft. 3-conductor shielded wire lead, spliced into AC wiring harness.
Certifications TSO-C106 (Incomplete)