82 Programmer
Chapter 2 Programming with Help Function
Canceling thread breakage at the last stitch
Addition of feed after the last point can cancel thread
breakage at the last stitch.
When "115" is input for the end code, the thread breakage does not occur. In this case, every
thread breakage including emergency stop is canceled. Carry out the following setting for
canceling thread breakage at the specified point.
Programming
1. Create the program 1 stitch (A) before the
desired end point.
2. Press
.
The number of pressing varies depending on the
programming method.
3. Select with and press .
4. Move the work clamp with
for the
stitch length. Press
when the needle point is
at point B of the pattern.
Point B is programmed.
5. Press .