Installation
Type 8792, 8793
english
13. PNEUMATIC CONNECTION
13.1. Safety instructions
DANGER!
Risk of injury from high pressure in the equipment.
Before loosening the pneumatic lines and valves, turn off the pressure and vent the pneumatic lines.
WARNING!
Risk of injury from improper installation.
Installation may be carried out by authorized technicians only and with the appropriate tools.
Risk of injury from unintentional activation of the system and an uncontrolled restart.
Secure system from unintentional activation.
Following installation, ensure a controlled restart.
Working connection 2
(connection: A2)
Supply pressure connection 1.4 – 7 bar
(connection: P)
Working connection 1 <
(connection: A1)
Deaeration connection
Figure 22: Fluid installation / Location of the connections