000 299 119 5 - BA ROLLANT 240 - 250 - 254 - 255 8.1.9
Setting up the baler
ROLLANT 240/250 up to 72507006, up to 74900805
ROLLANT 254/255 and 240/250 from 72507007 / 74900806
Hydraulic baling pressure preadjustment
The ROLLANT 240/250/245/255 RC is fitted with an
adjustable pressure-limiting valve (D), which controls
the baling pressure. The baling pressure can be
reduced or increased with the handwheel (A).
ROLLANT 240/250 (up to 72507006, up to 74900805)
The baling pressure can be set to a maximum of
130 bar (1885 psi) by turning the hand wheel all the
way in.
The baling pressure can be set to a minimum of 70 bar
(1015 psi) by turning the hand wheel all the way out.
ROLLANT 254/255 and ROLLANT 240/250
(from 72507007 / 74900806)
The baling pressure can be set to a maximum of
150 bar (2176 psi) by turning the hand wheel all the
way to the right.
The baling pressure can be set to a minimum of 70 bar
(1015 psi) by turning the hand wheel all the way to the
left.
(Fig. 20, 21)
D
A
20
D
A
21

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Claas ROLLANT 240 and is the answer not in the manual?

Claas ROLLANT 240 Specifications

General IconGeneral
BrandClaas
ModelROLLANT 240
CategoryLawn and Garden Equipment
LanguageEnglish

Related product manuals