000 299 119 5 - BA ROLLANT 240 - 250 - 254 - 255 9.2.7
Operation
Automatic wrapping
Note!
If control light (K) lights up or flashes quickly
after starting operation of the round baler, the
round baler is not ready for automatic wrapping.
Before binding correct the causes.
Possible causes:
The tailgate is open
The ramp is pressed down
The twine binding levers are not in the home
position.
Binding and ejecting bales
Once the bales have reached the specified
compression, the binding procedure begins
automatically.
The stop symbol (S) lights up and the signal generator
(A) emits a sound. The error message control light (K)
flashes.
The tractor must now be stopped within the delay
period until binding starts.
The binding twine or the net is then caught up by the
rotating bale and drawn in.
Note!
The delay time is the time period between
completion of the bale and the start of automatic
wrapping.
As soon as the binding process has finished, the stop
symbol light (S) goes out.
For twine binding, the end of the binding procedure is
also indicated by the fact that the twine guide lever has
stopped.
For net binding, the end of the binding process can
also be detected by the fact that the movement of roll
of netting ceases and the blade can be heard as it cuts
off the net.
(Fig. 10)
10

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Claas ROLLANT 240 and is the answer not in the manual?

Claas ROLLANT 240 Specifications

General IconGeneral
BrandClaas
ModelROLLANT 240
CategoryLawn and Garden Equipment
LanguageEnglish

Related product manuals