EasyManuals Logo

Claas ROLLANT 240 User Manual

Claas ROLLANT 240
284 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #191 background imageLoading...
Page #191 background image
000 299 119 5 - BA ROLLANT 240 - 250 - 254 - 255 11.2.3
CLAAS COMMUNICATOR
Setting the delay between end of baling and
start of net wrapping
The delay time between the end of the bale wrapping
and the start of the wrapping can be set between 1 and
10 seconds in steps of 0.1 second. This delay equals
the time needed to stop the machine.
Note!
If the delay is set to 10 seconds, the machine
will automatically switch to the operating mode
»Manual Tying«.
Turn the incremental encoder (I),
until the »delay time« (F) appears
surrounded by a frame.
Press the incremental encoder to
confirm. The frame appears
enlarged.
Turn the incremental encoder to
change the delay time.
Press the incremental encoder to
confirm the new value: the value
is saved. The frame is reduced in size.
(Fig. 5)
F
I
5
1.0
1.0

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Claas ROLLANT 240 and is the answer not in the manual?

Claas ROLLANT 240 Specifications

General IconGeneral
BrandClaas
ModelROLLANT 240
CategoryLawn and Garden Equipment
LanguageEnglish

Related product manuals