Page #146 background imageLoading...
Page #146 background image
9.2.8 BA ROLLANT 240 - 250 - 254 - 255 - 000 299 119 5
Operation
Ejection of bale:
The tailgate is opened by operation of the hydraulic
control valve.
The bale leaves the baling chamber via the bale
ejector (ramp).
As soon as the ramp is forced down by the bale, the
stop sign in control box (S) flashes and signal horn (A)
sounds.
Once the bale has left the ramp, both the stop sign in
control box (S) and signal horn (A) go out.
The tailgate is closed by operation of the hydraulic
control valve.
Once the tailgate is closed (can be audibly
recognized), the control light fault (K) will go out.
The next bale can be pressed.
(Fig. 10)
Laying down the bales
Danger!
Lay the bales down on a slope so that they
cannot start to move.
Bale counter
The bale counter (Z) shows the number of pressed
round bales. This system counts the completely
finished bales. Press the reset button (R2) to reset the
bale counter to "0".
(Fig. 11)
Z
R2
11