StartPCoolant [ Bar ] (PRP only)
Coolant pressure limit = one of the engine running indications.
To activate this function any Analog input must be configured to Analog logical input Coolant press.
Step: 0,1 Bar
Range: 0 10,0 Bar
Hint:
Step, Range and dimension depend on corresponding Analog input sensor characteristic.
Prestart Time [ s ]
Time the binary output Prestart is active prior to engine start (Start request sending to ECU). Set to zero if
you want to start immediately after Start button is pressed (the Prestart output stays opened). RPM must be
zero during Prestart time otherwise the Starting procedure is not activated.
Step: 1s
Range: 0 600 s
MaxCrank Time [ s ]
Amount of time the controller will crank the engine in an attempt to start.
Step: 1s
Range: 1 3600 s
Hint:
The ID-DCU MARINE stops cranking after three seconds when detected RPM = 0.
CrankFail Pause [ s ]
Pause between crank attempts.
Step: 1 s
Range: 1 200 s

Table of Contents

Other manuals for ComAp InteliDrive DCU Marine

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ComAp InteliDrive DCU Marine and is the answer not in the manual?

ComAp InteliDrive DCU Marine Specifications

General IconGeneral
BrandComAp
ModelInteliDrive DCU Marine
CategoryController
LanguageEnglish

Related product manuals