EasyManua.ls Logo

ComAp InteliDrive DCU Marine - Page 110

ComAp InteliDrive DCU Marine
168 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
ID-DCU-MARINE-2.2.2, ©ComAp June 2015 - 110 -
ID-DCU-MARINE-2.2.2.pdf
RunOnlyBlkDel3 [ s ]
Delay for Engine running Alarms activation group 3.
Step: 1s
Range: 0 60 s
BINARY INPUT
BinInp delay
physical
BINARY INPUT
closed
Internal value
Engine running
state
RunOnlyBlkDel
PROTECTION
active
inactive
BINARY INPUT
BinInp delay
physical
BINARY INPUT
closed
Internal value
Engine running
state
RunOnlyBlkDel
PROTECTION
active
inactive
Hint:
Engine running state =
RPM > Engine params: Starting RPM or
Analog input Oil Press > Engine params: Starting Poil or
Analog input Coolant Press > Engine params: StartPCoolant (PRP only) or
Active Binary input RunIndication1 or
Active Binary input RunIndication2 or
Active Binary input RunIndication3.
BinInp Delay 1 [ s ]
Binary input protection is activated when input is closed for longer time than BinInp delay 1. To use this filter
Binary input must be configured in DriveConfig for Property Delay = BinInp delay 1.
Step: 1s
Range: 0 60 s
BinInp Delay 2 [ s ]
Binary input protection is activated when input is closed for longer time than BinInp delay 2. To use this filter
Binary input must be configured in DriveConfig for Property Delay = BinInp delay 2.
Step: 1s
Range: 0 60 s