ID-DCU-MARINE-2.2.2, ©ComAp June 2015 - 127 -
ID-DCU-MARINE-2.2.2.pdf
Engine events
Note
Starts
Button start
Start from ID-DCU MARINE panel
CAN control + Button start
Start from I-RD-CAN-ID-DCU-MARINE
RS232 control + Button start
Start from InteliMonitor
Remote start
Start from BI
Stops
Engine stop
Stop from ID-DCU MARINE panel or BI
CAN control + Engine stop
Stop from I-RD-CAN-ID-DCU-MARINE
RS232 control + Engine stop
Stop from InteliMonitor
Remote start
ID-DCU MARINE binary input
Blackout start
ID-DCU MARINE binary input
Button start
ID-DCU MARINE panel button
Fault reset
ID-DCU MARINE panel button
LOC mode ON
ID-DCU MARINE panel button
LOC mode OFF
ID-DCU MARINE panel button
HRB mode ON
ID-DCU MARINE panel button
HRB mode OFF
ID-DCU MARINE panel button
RS232 control
Start, Stop, Fault reset, I/0 button from
InteliMonitor or I-RD-CAN-ID-DCU-
MARINE
Modem control
Start, Stop, Fault reset, On/Off from
Modem
SMS control
Received command from GSM modem
CAN control
Received command via CAN bus e.g.
from I-RD-CAN-ID-DCU-MARINE or IG-
IB / IB-NT
ActCallCH1-OK
Successful active call on channel 1
ActCallCH2-OK
Successful active call on channel 2
ActCallCH3-OK
Successful active call on channel 3
Extern start
Manual engine starter handling.
Engine stop
Engine changed state from
Emerg.man ON
Emergency manual mode ON
Emerg.man OFF
Emergency manual mode OFF
Clutch ON
Binary output clutch was closed
Clutch OFF
Binary output clutch was opened
Stop button
ID-DCU MARINE panel button
Switched on
Controller was switched on
Cfg loaded
Configuration archive was changed
FwLoaded
Firmware upgrade
Time stamp
Depends on setpoint setting period
Password set
Any level from any terminal
Password changed
Any level from any terminal
Access set
Access code was set
Access changed
Access code was changed
Watchdog
Controller internal watchdog protection
Param fail
Setpoints checksum fail
RTC battery
RTC battery fail
Hint:
Value name can’t exceed 11 characters to be recorded to History file with prefix (Wrn, Fls etc.). Longer
names characters are canceled.
Corresponding Sd BINx, Sd BOUTx or Sd AINx is indicated in Alarm list and history record when
communication with any extension units (IS-BIN, IS-AIN, IGS-PTM) is interrupted.
Example:
When IS-BIN16/8 is configured for addresses: Binary inputs = BIN1, BIN2 and Binary outputs = BOUT1, then
three messages Sd BIN1, Sd BIN2, Sd BOUT1 are indicated after communication is interrupted.