9. Rename output to RPM out.
10. Go to I/O window and configure analog SCM AOUT1 as RPM out. Then configure output convert Low
limit (0 RPM ~ 0.00V output) and High output convert limit (2000 RPM ~ 10.00V output).
Speed governor output characteristics for Lo limit and
Hi limit setting above.
Speed governor output voltage in this case (when
RPM1= 500 and RPM2=1800) is 9V when pressure is
low and 2,5V when pressure is high.
11. Final PLC layout in DriveConfig