Develop D 16G - Laser Emission Timing

Develop D 16G
239 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
M-20
9-3. Laser Emission Timing
When a READY signal is detected a given period of time after the print command has
been issued, the Controller/Mechanical Control Board outputs a laser ON signal.
The laser ON signal makes a laser beam to be emitted and the laser beam travels to the
Polygon Mirror, G1 Lens, and the SOS Mirror to eventually hit the SOS Sensor, which
generates an SOS signal.
The SOS signal determines the laser emission timing for each line in the main scanning
direction.
4136M517AA
SOS Mirror
SOS Sensor
Polygon Mirror
G1 Lens
Laser Unit

Table of Contents