EasyManua.ls Logo

Develop D 16G - Fusing Temperature Control; Temperature Changes (Plain Paper Having a Length of 186 MM or more; Temperature Control

Develop D 16G
239 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
M-26
12-2. Fusing Temperature Control
(1) Temperature changes (plain paper having a length of 186 mm or more)
(2) Temperature control
The fusing temperature is increased to a predetermined level during the warm-up cycle.
The warm-up control is provided when power is turned ON, the Front Door is opened and
closed, and the Energy Save mode is canceled.
In the standby state, the fusing temperature is set to a level (130 °C) lower than that dur-
ing a print cycle, thereby cutting down power consumption.
The temperature control mode when the control is resumed (when power is turned ON,
the Front Door is opened and closed, or the Energy Save mode is canceled) is set
according to the mode and the fusing temperature valid before the interruption.
In the Energy Save mode, the Fusing Roller Heater Lamp is turned OFF to reduce power
consumption.
Thermistor-detected temperature
at temperature control start
Less than 50 °C50 °C to 125 °C125 °C or more
Mode before
temperature
control
Power OFF, Front
Door open/close
Mode 0 Mode 0 Mode 0
Mode 0
Mode 1
Mode 2 Mode 3
Mode 1 Mode 1
Mode 2
Mode 2 Mode 3
Mode 3
130 °C
200 °C
Fusing Roller Temperature
Warm-up
Mode 1:
300 sec.
Mode 2:
208 sec.
Mode 3
In standby
During print
cycle (600 dpi)
Temperature detected by Thermistor
Mode 0:
180 sec.

Table of Contents

Related product manuals