System Status Commands
23-7
23
show system
This command displays system information.
Default Setting
None
Command Mode
Normal Exec, Privileged Exec
Command Usage
For a description of the items shown by this command, refer to “Displaying
System Information” on page 4-1.
The POST results should all display “PASS.” If any POST test indicates
“FAIL,” contact your distributor for assistance.
Example
Console#show system
System Description: 24/48 port 10/100/1000 Stackable Managed Switch
with 2 X 10G uplinks
System OID String: 1.3.6.1.4.1.259.8.1.9
System information
System Up time: 0 days, 1 hours, 23 minutes, and 44.61 seconds
System Name : [NONE]
System Location : [NONE]
System Contact : [NONE]
MAC Address (Unit1): 00-20-1A-DF-9C-A0
MAC Address (Unit2): 00-20-1A-DF-9E-C0
Web Server: Enabled
Web Server Port: 80
Web Secure Server: Enabled
Web Secure Server Port: 443
Telnet Server: Enable
Telnet Server Port: 23
Jumbo Frame: Disabled
Jumbo Frame Size: 1522
POST Result:
DUMMY Test 1 ................. PASS
DRAM Test .................... PASS
PCI Device 1 Test ............ PASS
I2C Bus Initialization ....... PASS
Fan Speed Test ............... PASS
Done All Pass.
Console#