7.4.6 Enable reviewing of results
Reviewing of results is available for Advanced horizontal alignment jobs and vertical
alignment jobs. Reviewing of results is not available when QuickSpec mode is activated.
See Section 7.5.5 for more information on reviewing alignment measurement results.
Procedure
1.
Activate an alignment job.
2. From the Laser Align Application main menu, press ALT.
3. Enable reviewing of results:
a. For horizontal alignment jobs, press F10 Job Flow > F12 Review Results.
b. For vertical alignment jobs, press F10 Review Results.
A selected button means the option is enabled.
7.4.7 Enable foot pre-check
Checking for soft foot is available only for Advanced horizontal alignment jobs.
Procedure
1. Activate a horizontal alignment job.
2. From the Laser Align Application main menu, press ALT > F10 Job Flow > F9 Foot Pre-
Check.
3. Use the up or down arrow keys to select a foot pre-check method to apply to the job
and press Enter.
See Foot pre-check for more information on the available foot pre-check methods.
7.4.8 Enable thermal growth option
Enabling the thermal growth option is available only for Advanced horizontal alignment
jobs. Thermal growth is not available when QuickSpec mode is activated.
Thermal growth can cause a machine alignment to change significantly when machines
are started from a “cold” position and run up to operating speed (“hot” position).
Procedure
1.
Activate a horizontal alignment job.
2. From the Laser Align Application main menu, press ALT > F10 Job Flow > F8 Thermal
Growth.
3. Select a thermal growth conversion option and press Enter.
Advanced Laser Alignment
192 MHM-97432 Rev 7