7.4.4 Select live move orientation
Selecting a live move orientation is available only for Advanced horizontal alignment jobs.
This option enables you to perform a live move in the orientation you selected. By default,
live move is enabled in the horizontal direction.
Procedure
1.
Activate a horizontal alignment job.
2. From the Laser Align Application main menu, press ALT > F10 Job Flow.
3. Press F10 Live Move to select from Horizontal Only or Vertical and Horizontal.
The selection for Live Move defaults to Horizontal Only, which is recommended for
most alignments. For special applications, you can switch to Vertical and Horizontal.
Selecting Horizontal Only displays the movement required to align the machines
horizontally.
Selecting Vertical and Horizontal displays the movement required to align the machines
in the vertical and horizontal direction.
See Section 7.5.10 for more information on performing a horizontal live move.
7.4.5 Enable live move alerts
Enabling live move alerts is available only for Advanced horizontal alignment jobs.
Live move alerts are enabled by default in vertical alignment and straightness
measurements.
When this option is enabled, the status LED on the analyzer flashes and an audible tone is
generated when the machine alignment condition reaches the target tolerance values.
Increasing and decreasing flashes indicate when the machine alignment crosses through
the acceptable and excellent tolerance condition thresholds. The number of flashes and
flash rate are consistent with the audible tone generated when the machine alignment
condition reaches the target tolerance values.
Prerequisites
Enable the Status Beeper option on the General Setup screen to hear the audible alerts.
Press Home > ALT > F2 General Setup > F3 Set Status Beeper.
Procedure
1. Activate a horizontal alignment job.
2. From the Laser Align Application main menu, press ALT > F10 Job Flow.
3. Press F11 Enable Alert to enable live move alerts.
A selected button means the alert is enabled.
Advanced Laser Alignment
MHM-97432 Rev 7 191

Table of Contents

Other manuals for Emerson CSI 2140

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Emerson CSI 2140 and is the answer not in the manual?

Emerson CSI 2140 Specifications

General IconGeneral
BrandEmerson
ModelCSI 2140
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals