4.10.6 View parameters in the Analysis Parameters (AP) set
You can view the parameters set up in the Analysis Parameter set in AMS Machinery
Manager. This includes the measured value, percent of fault, and any parameters that may
be in alert or fault.
Procedure
1.
Activate a route.
2. Ensure the desired measurement point is displayed.
3. From the Route Data Collection screen, press F11 View Parms.
A list of parameters appears under the Status field. The background color of the
alarm status indicates the severity relative to the alarm level.
4. Press F1 or F7 to move to another measurement point in the route, if necessary.
5. Press Enter.
4.11 Route reports
You can create and send route reports to AMS Machinery Manager or to a memory card
inserted into your analyzer. The route report displays information for all equipment and
their measurement points in the active route.
4.11.1 Print a route report to AMS Machinery Manager
A route report displays information for all equipment and their measurement points for
the active route. When you print a report from the analyzer, the report is saved to a file on
the AMS Machinery Manager computer.
Prerequisites
• On the analyzer, press Home > ALT > F2 General Setup > F6 Set Print Mode and ensure the
default print mode is set to Send to PC.
• Ensure the same connection type is set on the analyzer and in Data Transfer. The
Ethernet and Wireless options may require additional setup to connect to the
desired computer. See the Ethernet and Wireless sections and your IT group for
more information.
Procedure
1. Use the appropriate cable to connect your analyzer to a computer where AMS
Machinery Manager is installed, if you are using a wired connection.
2. On the computer, open Data Transfer.
3. Activate a route.
4. From the Route Data Collection screen, press ALT > F11 Print Route Report.
5. Select the data to include in the report.
Route
96 MHM-97432 Rev 7