Option Description
F9 Route Mgnt Load, delete, or activate routes. You can also connect to AMS Machinery
Manager Data Transfer.
F10 View Trend History Display trend data for the current point in a graphical format. The data
includes both historical data downloaded from the database and new data
collected with the analyzer.
F11 Print Route Report Send a route report to the memory card or to AMS Machinery Manager,
depending on the default print mode for the analyzer.
F12 More Point Info View information about the route and the current measurement point.
4.1.3 Route setup
Note
You cannot create or modify routes using the analyzer. Use AMS Machinery Manager to create or edit
routes.
• A route includes information from one area and is tagged to that area.
• A route does not need to include all equipment in an area or all points on the
equipment.
• Equipment can appear in more than one route, but cannot appear in the same route
more than once.
• The order of equipment in a route can differ from its order in the database area.
• The route points do not have to be in the same order as listed on the equipment.
• The route structure stores a list of equipment and measurement point IDs as they
are defined in the database. When you transfer a route, AMS Machinery Manager
searches the area for the equipment and points that match the route. The route
does not recognize points if their IDs are modified in the database. Loading the
route could cause problems.
4.2 Manage routes
4.2.1 Route Management
The Route Management screen lets you manage the routes in your analyzer. If you do not
have any routes activated, the Route Management screen appears when you open Route.
Otherwise, access it from the Route Data Collection ALT2 screen.
You can do the following:
• Load routes into the analyzer from AMS Machinery Manager Data Transfer.
• View routes saved in the analyzer.
• Activate a route.
Route
74 MHM-97432 Rev 7

Table of Contents

Other manuals for Emerson CSI 2140

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Emerson CSI 2140 and is the answer not in the manual?

Emerson CSI 2140 Specifications

General IconGeneral
BrandEmerson
ModelCSI 2140
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals