d. Press ALT > F3 Cursor Home to place the cursor to the first defined segment.
e.
Press ALT > F4 Clear Cursor to remove the cursor from the screen.
f. Press ALT > F9 Cursor End to place the cursor to the last defined segment.
g. Press the down arrow key on the analyzer to compress the Y axis by a factor of
two.
h. Press the up arrow key on the analyzer to expand the Y axis by a factor of two.
i. Press the left or right arrow keys on the analyzer to move the cursor to the next
segment to the left or right.
7.8 Plots
7.8.1 View tolerance plots
Tolerance plots are graphical representations of the alignment condition of the machine.
You can view the tolerance plots from the Review Measurements screen or from the
Horizontal Move, Vertical Move, Dual Move, Angular Move, and Offset Move screens.
Prerequisites
The following steps let you view the tolerance plot from the Review Measurements screen.
Make sure you have enabled reviewing of results. See Section 7.4.6.
Procedure
1. After acquiring alignment data, press Enter.
2. From the Review Measurements screen, press F8 Data Detail to display the tolerance
plot.
Advanced Laser Alignment
246 MHM-97432 Rev 7