Shim values are equivalent to raising the machine. In this case, all shim values are
positive. When correcting angular misalignment, keep the flange offset movement
to a minimum. After shimming is complete, re-tighten bolts and take a new set of
readings.
7.6 Vertical alignment
To complete a vertical alignment job:
1.
Define the alignment job:
a. Set up the job parameters.
b. Enter machine dimensions.
You can define the flange or customize the flange in this step.
2. Acquire alignment data.
You can review measurement results in this step.
3. View machine moves and align the machine.
You can perform a live move in this step.
7.6.1 Enter machine dimensions - vertical alignment
This is the first step in performing vertical alignment. After completing this step, the Enter
Dimensions function on the Laser Align Application main menu is marked with an X.