EasyManuals Logo

ETC Element 2 Operating Manual

ETC Element 2
649 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #259 background imageLoading...
Page #259 background image
Working with a Single Cue List 257
For Example:
You want the time for cue 1 to be 10 minutes and 15 seconds.
[Cue] [1] [Time] [1][0][1][5] [Enter]
The command line will show the time as:
If you want the time for cue 1 to be in seconds and tenths of a second, like 1.3 seconds, you
will type using a decimal.
[Cue] [1] [Time] [1][.][3] [Enter]
The command line will show the time as:
Setting Cue Level Timing
Unless you specify otherwise, Eos assigns default fade times to any cue you record. Default timing is
designated in Setup (Cue Settings (on page153)). Cue level timing can be applied when a cue is recor-
ded or can be added or modified later.
Following are some examples of record commands with cue level timing:
[Record] <Cue> [5] [Time] [9] [Enter] - puts a time of 9 seconds on all parameter timing cat-
egories.
[Record] <Cue> [6] [Time] [3] [Time] [9] [Enter] -specifies the intensity up, focus, color, and
beam times at 3 seconds and the down time at 9 seconds. The first instance of [Time] is used
for intensity up fade (meaning intensity value is fading to a higher level than previously set)
and the second instance of [Time] is used for intensity down fade time (intensity values fading
to a lower level than previously set).
[Record] <Cue> [2] [Time] [Enter] - resets time to default value and unsplits the time, making it
the same as the up fade.
Note: Unless FCB timing is specifically set, it always defaults to the up fade time value.
Manual Timing at a Cue Level
It is possible to assign a time of manual, for manual parameter transition through the associated
fader. See ManualTiming Control (on page321) for more information. Manual times are assigned by
using the {Manual} softkey that displays after [Time] is pressed when recording a cue.
[Record] <Cue> [4] [Time] {Manual} [Enter] - applies a manual time. If the cue had previously
been given split times, would apply a manual to the up fade, focus, color, and beam times. If
the cue had a single time, all of the timing would be manual and controlled by the fader.
[Record] <Cue> [4] [Time] [Time] {Manual} [Enter] - applies a manual intensity time to the
down fade.

Table of Contents

Other manuals for ETC Element 2

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ETC Element 2 and is the answer not in the manual?

ETC Element 2 Specifications

General IconGeneral
DMX Outputs2
TouchscreenYes
NetworkingEthernet
TypeLighting Control Console
Master Faders2
Encoders4
Ethernet Ports2
USB Ports4
Video OutputDisplayPort
Power Input100-240VAC, 50/60Hz
Power SupplyInternal
Control Channels6144
OutputArt-Net
DisplayMulti-Touch LCD
StorageSolid State Drive (SSD)

Related product manuals