142 Eos Family Operations Manual
The notifications you can see are:
A red “!” means that the dimmer/ device has errors, such as overtemp, breaker trip, and lamp
out.
Yellow “? means that the dimmer/ device has a warning message. Warning messages can
include:
Multiple devices’ addresses overlap
Multiple devices or different devices at this address
Patched fixture type mismatch
Patched fixture address mismatch
Offline
Detaching Devices
Pressing {Attach} twice will post the {Detach} command.
<Chan> [X] {Attach} {Attach} or <Address> [X] {Attach} {Attach} will remove the link between that
channel/address and the device at that address.
Clearing the Patch
You can clear the patch entirely by accessing the clear functions from Browser>Clear. The clear
functions window will open in the CIA.
To clear the patch, click {Clear Patch}. A confirmation is required before the patch will be cleared.

Table of Contents

Other manuals for ETC Element 2

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ETC Element 2 and is the answer not in the manual?

ETC Element 2 Specifications

General IconGeneral
DMX Outputs2
TouchscreenYes
NetworkingEthernet
TypeLighting Control Console
Master Faders2
Encoders4
Ethernet Ports2
USB Ports4
Video OutputDisplayPort
Power Input100-240VAC, 50/60Hz
Power SupplyInternal
Control Channels6144
OutputArt-Net
DisplayMulti-Touch LCD
StorageSolid State Drive (SSD)

Related product manuals