7020 'In Setting: D required'
DETECTION During execution.
CAUSE In Setting mode, the edge of the tool must be specified.
SOLUTION Program the edge.
7021 'In Setting: D alone not allowed'
DETECTION During execution.
CAUSE A "D" cannot be programmed alone in unload mode.
SOLUTION It cannot be programmed like this.
7022 'In Setting: M6 not admitted'
DETECTION During execution.
CAUSE In Setting mode, the M6 is not programmed
SOLUTION It cannot be programmed like this.
7023 'In load mode: M6 required'
DETECTION During execution.
CAUSE Two consecutive T's have been programmed in load mode.
SOLUTION In this mode, an M6 must be programmed after the T.
7024 'In unload mode: T0 not admitted'
DETECTION During execution.
CAUSE T0 cannot be programmed when the magazine is in unload mode.
SOLUTION Program the T to be unloaded.
7025 'In unload mode: M6 required'
DETECTION During execution.
CAUSE Two consecutive T's have been programmed in unload mode.
SOLUTION In this mode, an M6 must be programmed after the T.
7026 'In unload mode: This tool is already loaded'
DETECTION During execution.
CAUSE In unload mode, a tool has been programmed that is not in the magazine.
SOLUTION Program a T that is already in the magazine.
7027 M6 without T'
DETECTION During execution.
CAUSE An M6 has been detected without its corresponding T. There is machine parameter
whose value indicates what to do in this situation. If = 0, no error is issued; if = 1 a
warning is issued and if = 2 an error is issued.
SOLUTION First program the T or change the parameter value.
7028 T0 not admitted'
DETECTION During execution.
CAUSE T0 not allowed in a turret type magazine. In this type of magazine, the tool changes
are made by rotating the turret. Just program the T.
SOLUTION Do not program T0.
7029 'The operation could not be carried out: Error at the tool manager'
DETECTION During execution.
CAUSE Emergency at the tool magazine. It may be because the PLC has activated an invalid
maneuvering mark, because the PLC has activated SETTMEM or because there is
an internal error in the logic.
SOLUTION This error comes up due to an invalid maneuver when changing the tool. The solution
in this case, is to correct the change maneuver in the PLC program. In the case of
SETTMEM, check why the PLC has set the emergency signal.