3036 'Wrong gear change process'
DETECTION During execution.
CAUSE The spindle gear in the CNC's history and the one indicated by the PLC as being
active are not the same.
SOLUTION Check the PLC program.
3037 'Axis locked'
DETECTION During execution.
CAUSE The axis tries to move, but the SERVO is not ON.
SOLUTION Check the treatment of the SERVO signal in the PLC program or increase the value
of the DWELL parameter of the axis.
3038 'Too many parameters pending to be reported'
DETECTION During execution.
CAUSE The system is overloaded.
SOLUTION Close the Windows applications not related to the CNC. Contact Fagor.
3039 'The stop block has not been found in the block search'
DETECTION While executing in dry run.
CAUSE When executing the program in dry run, it does not go through the stop block.
SOLUTION Change the stop block.
3040 'Hirth axis positioned wrong'
DETECTION During execution.
CAUSE The Hirth axis is not positioned in a multiple number of its step.
SOLUTION Position the Hirth axis properly in a valid position or cancel it as Hirth axis.
3041 'No spindle has been defined for G33/G95'
DETECTION During execution.
CAUSE Functions G33 and G95 need a spindle to work. This spindle is by default the master
spindle of the channel, but if PLC register SYNC indicates another spindle, it works
with the latter.
If at a particular moment, none of the two is defined, an error is issued.
SOLUTION Assign a spindle to the PLC register or have a master spindle defined in the channel.
3043 'Spindle in M5 when activating electronic threading'
DETECTION During execution.
CAUSE The spindle involved in electronic threading (G33) is in M5 by default, or an M5 has
been programmed in the same block as the G33.
SOLUTION Program a spindle rotation first or in the same block as the G33 indicating the turning
direction (M3/M4) or the speed (S).
3500 'Linear acceleration of section 1 smaller than or equal to zero'
DETECTION On startup or during execution.
CAUSE A zero acceleration has been programmed.
SOLUTION Program a positive value for the acceleration.
3501 'Linear acceleration of section 1 greater than the maximum'
DETECTION During startup or execution.
CAUSE An acceleration greater than the maximum has been programmed.
SOLUTION Program a smaller value than the maximum for the acceleration.
3502 'Linear acceleration of section 2 smaller than or equal to zero'
DETECTION On startup or during execution.
CAUSE A zero acceleration has been programmed.
SOLUTION Program a positive value for the acceleration.
3503 'Linear acceleration of section 2 greater than the maximum'
DETECTION During startup or execution.
CAUSE An acceleration greater than the maximum has been programmed.
SOLUTION Program a smaller value than the maximum for the acceleration.