EasyManua.ls Logo

Fagor CNC8 070 - 1553 Too Many User Variables; 1700 Center Punching: F = 0; 1701 Center Punching: S = 0; 1554 The PLC Has Not Recognized the START in a #EXEC Instruction

Fagor CNC8 070
134 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
CNC8070
R
EF
. 0402
E
RROR
SOLUTIONS
Page 61 of 128
Errors 1000-1999
1553 'Too many user variables'
DETECTION During execution.
CAUSE The maximum number of user variables (V.P, V.S) that can be defined has been
exceeded.
SOLUTION The maximum number of user variables that can be defined is 20.
1554 'The PLC has not recognized the START in a #EXEC instruction'
DETECTION Execution of #EXEC instruction.
CAUSE When giving the order to execute a program in another channel, the PLC must give
the "go ahead" to the program start-up (START) If it doesn't give this go-ahead, it will
issue this error.
SOLUTION Check everything that could prevent, via PLC, the execution of a program in that
channel.
1700 'CENTER PUNCHING: F = 0'
DETECTION Executing the center-punching cycle.
CAUSE F programmed in the cycle equal to 0.
SOLUTION Assign a value greater than 0.
1701 'CENTER PUNCHING: S = 0'
DETECTION Executing the center-punching cycle.
CAUSE S programmed in the cycle equal to 0.
SOLUTION Assign a value greater than 0.
1702 'CENTER PUNCHING: T = 0'
DETECTION Executing the center-punching cycle.
CAUSE No tool T has been programmed in the cycle.
SOLUTION Assign a tool T.
1703 'CENTER PUNCHING: P = 0'
DETECTION Executing the center-punching cycle.
CAUSE P (depth) programmed in the cycle equal to 0.
SOLUTION Assign a value greater than 0.
1704 'CENTER PUNCHING: ALPHA = 0'
DETECTION Executing the center-punching cycle.
CAUSE Angle alpha programmed in the cycle equal to 0.
SOLUTION Assign a value greater than 0.
1705 'CENTER PUNCHING: DIAMETER = 0'
DETECTION Executing the center-punching cycle.
CAUSE Diameter programmed in the cycle equal to 0.
SOLUTION Assign a value greater than 0.
1706 'DRILLING 1: F = 0'
DETECTION Executing drilling cycle 1.
CAUSE F programmed in the cycle equal to 0.
SOLUTION Assign a value greater than 0.
1707 'DRILLING 1: S = 0'
DETECTION Executing drilling cycle 1.
CAUSE S programmed in the cycle equal to 0.
SOLUTION Assign a value greater than 0.
1708 'DRILLING 1: T = 0'
DETECTION Executing drilling cycle 1.
CAUSE No tool T has been programmed in the cycle.
SOLUTION Assign a tool T.

Table of Contents