Errors 0000-0999
0105 'Parameters cannot be validated while executing a program'
DETECTION During execution.
CAUSE An attempt has been made to validate a machine parameter table while the program
is in execution or interrupted.
SOLUTION Finish or abort the program in order to be able to validate the machine parameter
table.
0150 'Too many open files'
DETECTION While executing a part-program with external subroutines.
CAUSE The number of open files (main program plus external subroutines) is greater than 20.
SOLUTION Decrease the number of external subroutines open in the part-program at the same
time.
0151 'Writing access denied'
DETECTION Access to a file.
CAUSE An attempt has been made to write into a file that has no writing permission.
SOLUTION Give the file writing permission.
0152 'The file cannot be open'
DETECTION Access to a file.
CAUSE A file could not be opened for reading or writing.
SOLUTION Check that the file exists in the directory and that it has the right permissions for the
action to be carried out.
Check that the file is not corrupted by some previous action.
0153 'Reading access denied'
DETECTION Access to a file.
CAUSE An attempt has been made to read into a file that has no reading permission.
SOLUTION Give the file reading permission.
0160 'Axis/Set not available in the system'
DETECTION Execution of the commands SET AX, CALL AX, G112.
CAUSE When changing axis configurations or parameter sets, an attempt has been made
to access a nonexistent axis or parameter set, or an axis currently associated with
another channel.
SOLUTION Do not access the unavailable axis or parameter set or free the axis in the other
channel using a FREE AX.
0168 'LR Overflow'
DETECTION In the position loop of Sercos axes.
CAUSE The position loop of the Sercos axes exceeds the time allowed.
SOLUTION Adjust parameter LOOPTIME.
0200 'Failure when requesting a VxD'
DETECTION When reading the battery status.
CAUSE It is not possible to connect with VcompciD.
SOLUTION Contact your supplier.
0201 'Mains failure. PC powered by a battery'
DETECTION When reading the battery status.
CAUSE The mains supply to the PC has dropped and it is now powered by the battery.
SOLUTION If the mains failure fortuitous, is look for possible causes. If it is caused by the operator,
let the automatic PC-turn-off sequence run to its completion.
Whether the mains failure is fortuitous or caused by the operator, let the automatic
PC-turn-off sequence run to its completion. If the mains failure is fortuitous, look for
the possible causes.