EasyManua.ls Logo

Fagor CNC8 070 - 8209 Wrong Active Axis; 8210 Integer Limits Exceeded; 8211 The Limits of the Whole Portion Have Been Exceeded; 8212 The Limits of the Fractional Portion Have Been Exceeded

Fagor CNC8 070
134 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
CNC8070
R
EF
. 0402
OF 128
E
RROR
SOLUTIONS
Page 112 of 128
Errors 8000-8999
8209 'Wrong active axis'
DETECTION During editing.
CAUSE The axis name has been programmed with the wrong wild character.
SOLUTION The names of the axis with wild character are @1 through @5.
8210 'Integer limits exceeded'
DETECTION During editing.
CAUSE The programmed integer value is too high.
SOLUTION The maximum value for an integer is 4294967295.
8211 'The limits of the whole portion have been exceeded'
DETECTION During editing.
CAUSE The whole portion of the number has the wrong value.
SOLUTION The range of valid values for the whole portion of a number is ±99999.
8212 'The limits of the fractional portion have been exceeded'
DETECTION During editing.
CAUSE The decimal portion of the number has the wrong value.
SOLUTION The range of valid values for the decimal portion of a number is ±0.99999.
8213 'The format of the fractional portion have been exceeded'
DETECTION During editing.
CAUSE The maximum number of decimals allowed in a number has been exceeded.
SOLUTION The maximum number of decimals allowed in a number is 5.
8214 'Unknown flow controlling instruction'
DETECTION During editing.
CAUSE The instruction programmed after the "$" is wrong.
SOLUTION Check the syntax of the instruction.
8218 'Wrong character'
DETECTION During editing.
CAUSE An invalid character has been detected in the block.
SOLUTION Check the syntax of the block.
8221 'Syntax Error'
DETECTION During editing and execution in MDI.
CAUSE Wrong syntax of the programmed instruction or variable.
SOLUTION Check the syntax of the instruction or variable in the programming manual.
8222 'Nonexistent M function'
DETECTION During editing.
CAUSE The programmed M function does not exist.
SOLUTION Check the existing M functions in the programming manual.
8223 'The M functions are mutually exclusive or identical'
DETECTION During editing and execution in MDI.
CAUSE The possible causes are:
The same M function has been programmed more than once in the same block.
Incompatible M functions have been programmed in the same block.
SOLUTION The solutions are:
An M function can only be programmed once in a block.
Refer to the programming manual to check the incompatibility of the M functions.
8224 'M function out of range'
DETECTION During editing.
CAUSE The programmed M function does not exist.
SOLUTION Check the existing M functions in the programming manual.

Table of Contents