Page 54 of 128
Errors 1000-1999
1493 '#SPLINE ON, G41/G42 and G136 cannot be programmed at the same time'
DETECTION During execution.
CAUSE An attempt has been made to activate functions #SPLINE ON, G41, G42 and G136
at the same time at the CNC.
SOLUTION Cancel some of these functions.
1494 'Wrong index'
DETECTION During execution.
CAUSE The error number indicated in the #ERROR or #WARNING instruction does not exist.
SOLUTION Check the program.
1495 '#PROBE1: wrong axis for probing cycle'
DETECTION During execution.
CAUSE The PROBE1 cycle issues the error because the main three axes of the current
configuration are not the same as the main three axes of the initial configuration.
SOLUTION Go back to the initial configuration for the first three axes of the channel.
1496 '#PROBE1: programming not allowed while #TOOL AX[-] is active'
DETECTION During execution.
CAUSE An attempt has been made to execute the PROBE1 cycle while the tool is oriented
in the negative direction of the axis.
SOLUTION Program #TOOL AX[+] before executing the PROBE1 cycle to orient the tool in the
positive direction of the axis.
1497 'Wrong operator for the type of variable'
DETECTION During execution.
CAUSE An attempt has been made to change the value of the variable AXISNAMEi,
GAXISNAMEi, SPDLNAMEi or GSPDLNAMEi using the operators "+=", "-=", "*=" y
"/=".
SOLUTION Check the program.
1499 'Too many nesting levels of #RPT and subroutines'
DETECTION During execution.
CAUSE It is considered nesting when the #RPT instruction is programmed between two labels
that defined the influence area of another #RPT Bearing this in mind, the error comes
up because the number of nesting levels of RPT instructions and subroutines, if any,
has been exceeded.
SOLUTION The maximum number of nesting levels allowed is 20.
1500 '#EXEC: the program cannot be executed in the indicated channel'
DETECTION During execution.
CAUSE An attempt has been made to execute a program with #EXEC in a channel that:
Where another program is being executed.
That is in error.
Was in manual and cannot switch to automatic mode.
SOLUTION Wait for the program to finish in the other channel or reset it.
1501 'Labels repeated in #RPT'
DETECTION During execution.
CAUSE In the #RPT instruction, the starting and finishing labels are the same.
SOLUTION Define different starting and finishing labels.
1502 'The variable requires programming an array index'
DETECTION During execution.
CAUSE A variable has been programmed, but no index has been indicated for which to read
or write a variable.
SOLUTION Refer to the programming manual for control variables.