Page 74 of 128
Errors 1000-1999
1849 'RECTANGULAR POCKET: Finishing stock DELTA greater than the pocket'
DETECTION Executing a rectangular pocket.
CAUSE The defined pocket cannot be executed because half the shorter length of the pocket
minus the tool radius is smaller than the finishing stock in the work plane (DELTA).
SOLUTION Decrease the value of DELTA.
1850 'Lx must be multiple of Ix'
DETECTION Executing cycles G160 and G161.
CAUSE The length of the straight line or the rectangle must be multiple of the distance
between machining operations Ix. Otherwise, the machining operations will not be
equidistant.
SOLUTION Modify the values of Lx and Ix.
1851 'Ly must be multiple of Iy'
DETECTION Executing cycles G160 and G161.
CAUSE The length of the straight line or the rectangle must be multiple of the distance
between machining operations Iy. Otherwise, the machining operations will not be
equidistant.
SOLUTION Modify the values of Ly and Iy.
1852 'No tool has been programmed'
DETECTION Executing a calibration cycle (#PROBE1/2) or measuring cycle (#PROBE 3-9).
CAUSE No tool has been loaded into the spindle before executing the cycle.
SOLUTION Execute the cycle with a tool in the spindle (#PROBE1) or with a probe (#PROBE 2-9).
1853 'The probe signal has not been received'
DETECTION Executing a #PROBE cycle.
CAUSE While executing a #PROBE cycle, no point has been probed during a probing move.
SOLUTION Modify the geometric parameters of the cycle so the probe actually touches the tool
(#PROBE1) or the part (#PROBE 2-9).
1854 'The diameter J must be greater than zero'
DETECTION Executing a #PROBE 2 or a #PROBE 9 cycle
CAUSE A negative diameter has been programmed.
SOLUTION Assign a positive value.
1855 'Tool diameter greater than that of the hole'
DETECTION Executing a #PROBE 2 or a #PROBE 9 cycle
CAUSE The programmed diameter of the hole to be measured or that of the hole used to
calibrate the probe is smaller than the diameter of the probe used in measurement.
SOLUTION Assign a proper value.
1856 'Wrong withdraw distance E'
DETECTION Executing a #PROBE 2 or a #PROBE 9 cycle
CAUSE The withdraw distance cannot be negative and cannot exceed the diameter of the
hole.
SOLUTION Assign to E a value between 0 and the diameter of the hole.
1857 'There is no tool offset selected'
DETECTION Execution of the calibration cycle (#PROBE1/2).
CAUSE A tool calibration cycle or probing cycle has been executed without previously loading
a tool offset (D).
SOLUTION Program the tool offset D before calling the cycle.
1859 'The active plane for calibrating the probe must be G17, G18 or G19'
DETECTION Executing the #PROBE 2 cycle.
CAUSE When starting the probe calibration cycle, G20 is active.
SOLUTION Program G17 (XY plane), G18 (ZX plane) or G19 (YZ plane) before calling the cycle.