CNC8070
R
EF
. 0402
OF 128
E
RROR
SOLUTIONS
Page 92 of 128
Errors 3000-3999
3807 'Incremental jog index out of range (switch positions 1-5)'
DETECTION During execution.
CAUSE An attempt has been made to set via PLC an incremental jog position that is out of
the permitted range.
SOLUTION Check the writing of PLC.INCJOGIDX from the PLC.
3808 'The axis does not exist or is not available'
DETECTION During execution.
CAUSE The possible causes are:
1. The axis was not in jog mode when quitting that mode.
2. A G101 has been programmed on a slave axis of a Gantry pair.
3. A G102 has been programmed on a slave axis of a Gantry pair.
SOLUTION The first case is solved with a Reset.
3809 'Zero spindle speed programmed in G95'
DETECTION During execution.
CAUSE An attempt has been made to move an axis in continuous or incremental jog while
G95 is active and the speed programmed for the spindle to be synchronized is zero.
SOLUTION Program a speed for the spindle involved in the synchronization, either selected by
the PLC in the SYNC register or the master spindle.