‘Unresolved profile’
CAUSE The profile to be saved is not resolved completely either when “FINISHING” or when
“SAVING AND CONTINUING”
SOLUTION Resolve the profile to be saved. Only resolved profiled may be saved.
‘Insufficient memory’
CAUSE There isn’t enough system memory to go on with the profile editor.
‘Geometry error’
CAUSE Wrong geometry when accessing the profile editor with a selected profile. The
selected profile has some erroneous data in the path definition.
SOLUTION Correct the profile. All the paths that defined the profile must be properly defined.
‘Error in element data’
CAUSE The data entered in an element are not correct.
SOLUTION Correct the data of the element.
‘Error in profile data’
CAUSE Wrong data when editing a “circular” or “rectangular” profile.
SOLUTION Correct the data of the element.
‘The arc does not go through its starting coordinate’
CAUSE In an arc element, the data for the center, radius and starting point are not coherent.
SOLUTION Correct the data of the element.
‘The arc does not go through its final coordinate’
CAUSE In an arc element, the data for the center, radius and final point are not coherent.
SOLUTION Correct the data of the element.
‘There is no arc that complies with all the data’
CAUSE No arc can be found that is coherent with the known data.
SOLUTION Correct the data of the element.
‘Element not tangent to the previous one’
CAUSE The data entered in an element tangent to the previous element is not coherent.
SOLUTION Correct the data of the element.
'Wrong value’
CAUSE The value entered to modify a corner (rounding, chamfer, tangential entry or
tangential exit) is wrong.
SOLUTION Correct the data of the element. The value of the corner must be lower than the paths
where it has been defined.