CNC8070
R
EF
. 0402
E
RROR
SOLUTIONS
Page 1 of 128
Errors 0000-0999
ERRORS 0000-0999
0001 'SYSTEM ERROR'
DETECTION During execution.
CAUSE Software or hardware error that cause corrupt data and/or incoherent results.
SOLUTION This type of errors usually force the CNC output.
Contact your supplier.
0002 'SYSTEM WARNING'
DETECTION During execution.
CAUSE Warning of internal situations that could become system errors.
SOLUTION They're usually restored with a simple ESCAPE.
Contact your supplier.
0003 'Error when requesting memory'
DETECTION On CNC power-up.
CAUSE The CNC does not have enough memory.
SOLUTION Contact your supplier.
0004 'Checksum error in PLC data'
DETECTION On CNC power-up.
CAUSE The PLC data saved into a disk are not valid. The file containing the data (\FagorCNC\
PLC8070\ User\ project\ objects\ plcData.bin) is either missing, cannot be accessed
or is damaged. As a result, some PLC data (marks, counters, timers and registers)
has been lost.
SOLUTION If the error persists after powering the CNC up several times, contact your supplier.
0005 'The CNC was not turned off properly, it must be homed'
DETECTION On CNC power-up.
CAUSE The CNC data saved into a disk are not valid (coordinates, offsets, PARTC). The file
containing the data (\FagorCNC\ Data\ orgData.tab) is either missing, cannot be
accessed or is damaged. As a result, some data has been lost. It loses the values
for coordinates, offsets, PARTC, kinetics, etc.
SOLUTION If the error persists after powering the CNC up several times, contact your supplier.
0020 'Wrong access to a variable'
DETECTION CNC power-up or page change at the interface.
CAUSE A variable is been accessed that is not recognized by the CNC.
SOLUTION Contact the machine manufacturer or the person who designed the interface screens
to remove the access to a variable unrecognized by the CNC.