1464 'Programmed rotary axis out of the range of the module'
DETECTION During execution.
CAUSE The absolute coordinate (G90) programmed for the MODULE type rotary axis is
wrong.
SOLUTION The coordinate programmed for the axis must be between the limits set by its machine
parameters MODUPLIM and MODLOWLIM.
1465 'Functions RTCP and TLC are incompatible with each other'
DETECTION During execution.
CAUSE While one of the two functions was active, an attempt has been made to activate the
other one.
SOLUTION Both functions cannot be active at the same time.
1466 'G8 cannot be programmed as second motion block for G36/G37/G38/G39'
DETECTION During execution.
CAUSE A G8 block cannot be the second motion block of one of the functions
G36/G37/G38/G39. On one hand, these functions do not have an intermediate block
to make the path joining two blocks and, on the other hand, function G8 does not have
a previous block to be tangent to.
SOLUTION The second motion block of a G36/G37/G38/G39 function must be G0/G1/G2/G3.
1467 'POSLIMIT/NEGLIMIT cannot exceed the value of the machine parameter'
DETECTION During execution.
CAUSE The value to be written in variables A.POSLIMIT.axis and A.NEGLIMIT.axis cannot
exceed the value of machine parameters POSLIMIT and NEGLIMIT for that axis.
SOLUTION Check the program.
1468 'G30: Polar origin programmed wrong'
DETECTION During execution.
CAUSE Only one of the coordinates of the Polar origin has been programmed.
SOLUTION The coordinates of the Polar origin must be programmed in both main axes.
1469 'Negative or zero radius not allowed'
DETECTION During execution.
CAUSE A movement has been programmed in Polar coordinates, but the Polar radius is
negative or zero.
SOLUTION The Polar radius must always be greater than zero. When programming in
incremental mode, the programmed value may be negative or zero, but not the
absolute Polar radius.
1470 'UNIDIR rotary axis programmed wrong in incremental mode'
DETECTION During execution.
CAUSE The incremental coordinate programmed for the MODULE and UNIDIR type rotary
axis is wrong.
SOLUTION If machine parameter UNIDIR of the rotary axis is POSITIVE, the incremental
coordinate must be programmed with a positive or zero value. If machine parameter
UNIDIR of the rotary axis is NEGATIVE, the incremental coordinate must be
programmed with a negative or zero value.
1471 'G73: Rotation center programmed wrong'
DETECTION During execution.
CAUSE Only one of the two coordinates of the pattern (coordinate system) rotation has been
programmed.
SOLUTION The coordinates of the rotation center must be programmed in both main axes.
1472 'G73: The rotation angle has not been programmed'
DETECTION During execution.
CAUSE The coordinates of the rotation center have been programmed, but not the rotation
angle.
SOLUTION The coordinate system rotation angle must be programmed together with the
coordinates of the rotation center in both main axes.